CEM-C21, three-phase energy meter

Code: Q22332.

  •  Módules: 4
  •  Tariff: 1
  •  Certification: IEC
  •  Transistor output: 1
  •  System: Three-phase
  •  Measure: Direct
  •  Measurement Range (V): 3 x 127/220...3 x 230/400
  •  Input current: 5 (65) A

DATA  SHEET       ⬇️

USER MANUAL    ⬇️

PFC controllers PFR 6S / PFR 12S

165,000.00
Measurement: THD Plug & Play: yes Alarm up to: 10 alarms FCP system: yes Interface: display, keyboard 4 quadrant PFC: yes Supply and measuring voltage: 400 VAC ± 10%, 50 / 60 Hz Current measurement circuit: CT, IN / 5 Accuracy of voltage measurement: 1% Accuracy of current measurement: 1% Accuracy of cos measurement: ±2% Display: 27 electrical variables Relay outputs: 6 or 12, 1 A, 250 V, 250 W Protection degree: IP 40 Dimensions: 144 x 144 x 55 mm Connection: 6 / 12 - steps regulation

TCM-T150 Digital Power Analyzer

140,000.00
TCM-T150 Digital Power Analyzer with RS-485, 31st Order of Harmonics and Analogue output

CVM-A1500A-ITF-485-ICT2

1,450,000.00
Description   CVM-A1500 is a panel mounted power quality analyzer with EMS (Energy Management Software) integrated. Its internal Web Server (html5)

CLZ-FP-46/30-HD

183,000.00
CLZ-FP-46/30-HD, Three-phase tubular power capacitor

Code: R2H55N.

  •  Terminal: B
  •  Frequency (Hz): 50
  •  kvar (440 V): 27,4
  •  kvar (460 V): 30
  •  Use voltage (V): 460

Resort 2021

CEM-C21

CEM-C21, three-phase energy meter

Code: Q22332.

  •  Módules: 4
  •  Tariff: 1
  •  Certification: IEC
  •  Transistor output: 1
  •  System: Three-phase
  •  Measure: Direct
  •  Measurement Range (V): 3 x 127/220...3 x 230/400
  •  Input current: 5 (65) A

DATA  SHEET       ⬇️

USER MANUAL    ⬇️

PFC controllers PFR 6S / PFR 12S

165,000.00
Measurement: THD Plug & Play: yes Alarm up to: 10 alarms FCP system: yes Interface: display, keyboard 4 quadrant PFC: yes Supply and measuring voltage: 400 VAC ± 10%, 50 / 60 Hz Current measurement circuit: CT, IN / 5 Accuracy of voltage measurement: 1% Accuracy of current measurement: 1% Accuracy of cos measurement: ±2% Display: 27 electrical variables Relay outputs: 6 or 12, 1 A, 250 V, 250 W Protection degree: IP 40 Dimensions: 144 x 144 x 55 mm Connection: 6 / 12 - steps regulation

TCM-T150 Digital Power Analyzer

140,000.00
TCM-T150 Digital Power Analyzer with RS-485, 31st Order of Harmonics and Analogue output

CVM-A1500A-ITF-485-ICT2

1,450,000.00
Description   CVM-A1500 is a panel mounted power quality analyzer with EMS (Energy Management Software) integrated. Its internal Web Server (html5)

CLZ-FP-46/30-HD

183,000.00
CLZ-FP-46/30-HD, Three-phase tubular power capacitor

Code: R2H55N.

  •  Terminal: B
  •  Frequency (Hz): 50
  •  kvar (440 V): 27,4
  •  kvar (460 V): 30
  •  Use voltage (V): 460