Collections

Pre Fall 2021

Faucibus parturient dignissim nisi, magna ullamcorper facilisi tincidunt nulla et morbi sed in risus vestibulum consectetur arcu id eu pulvinar quis turpis luctus congue vitae ipsum egestas nunc, ornare massa commodo.

Spring-Summer
2021

Split Current Transformer

  • Standard and push button open type
  • Saleable terminal blocks
  • Insulation voltage 3 KV
  • Operating frequency 50/60 HZ
  • Dynamic current: Idyn = 2.5 Ith
  • Thermal short circuit current: Ith = 20 In
  • Maximum operating voltage: 0.72kV
  • V0 self extinguishing polycarbonate box

CVM-A1500-ITF-485-ICT2

1,450,000.00
CVM-A1500-ITF-485-ICT2, Power quality analyzers with recording of quality events and transients in accordance with (IEC 61000-4-30 Ed.2) Class A

Code: M56311.

  •  Protocol: Modbus/RTU | BACnet | webserver (HTTP) | XML | HTML5
  •  Memory: 200 MB
  •  Memory: Yes
  •  Events / Waveform: Yes
  •  Certification: -
  •  Energy accuracy: 0,2S (.../5A)
  •  Communications: RS-485 | Ethernet
  •  Transistor output: 2
  •  Nº relays: 2
  •  Digital inputs: 2
  •  Harmonics: 63
  •  Input current: .../5 A | .../1 A | 250 mA
  •  Mounting: Pannel
  •  Modules: 144 x 144

DJV-96T(96/96)

G-Digital 3 Phase AC Volt & Ampere Meters 5V – 300V It Shows the Voltage Values Between Phase-Neutral and Phase-Phase

MED1 Series

Klemsan MED1 series devices are MID approved energy meters that measure and record the basic electrical parameters required for monitoring a single-phase electric power line. • Voltage • Current • Frequency • Active power • Reactive power • Apparent power • Power factor • THDV • THDI • 4 quadrants energy

PFC controllers PFR 6S / PFR 12S

165,000.00
Measurement: THD Plug & Play: yes Alarm up to: 10 alarms FCP system: yes Interface: display, keyboard 4 quadrant PFC: yes Supply and measuring voltage: 400 VAC ± 10%, 50 / 60 Hz Current measurement circuit: CT, IN / 5 Accuracy of voltage measurement: 1% Accuracy of current measurement: 1% Accuracy of cos measurement: ±2% Display: 27 electrical variables Relay outputs: 6 or 12, 1 A, 250 V, 250 W Protection degree: IP 40 Dimensions: 144 x 144 x 55 mm Connection: 6 / 12 - steps regulation

Resort 2021

MYeBOX-1500-4 FLEX-R80

5,000,000.00
MYeBOX-1500-4 FLEX-R80, Portable power analyzer with recording of quality events and transients

Code: M8405E.   CONSULTAR DISPONIBILIDAD

  •  Nr Sensors: 4 FLEX-R80
  •  Communications: Wi-Fi | 3G
  •  Transistor output: 2
  •  Digital inputs: 2
  •  No. of voltage measurement inputs: 5
  •  Measuring current Channels: 5
  •  Class: According to Class A

DAV-72D

Direct Ammeter and Voltmeter with 2×3 Digit LED Display

TCM-T150 Digital Power Analyzer

140,000.00
TCM-T150 Digital Power Analyzer with RS-485, 31st Order of Harmonics and Analogue output

AFQm-4WF-100M-400

13,884,653.00
AFQm-4WF-100M-400, Active multifunctionfilter, 4 wires

Code: R7RM2F.

  •  System: 4 wires, 230...400 V
  •  Phase current (A): 100
  •  Peak current (A): 200
  •  Max.neutral current (A): 300
  •  Mounting: Wall-mounted

CEM-C12c

180,000.00
CEM-C12c, Single-phase energy meter, direct connection

Code: Q27211.

  •  Protocol: Modbus/RTU
  •  Módules: 1
  •  Certification: IEC
  •  Communications: RS-485
  •  System: Single-phase
  •  Measure: Direct
  •  Measurement Range (V): 1 x 230
  •  Measurement Range (A): 5 (100) A
  •  Quadrants: 4

 

CLZ-FP-44/12,5-HD

70,000.00

CLZ-FP-44/12,5-HD, Three-phase tubular power capacitor

Code: R2H54D.

  •  Terminal: A
  •  Frequency (Hz): 50
  •  kvar (400 V): 10
  •  kvar (440 V): 12,5
  •  Cover (opc.): 1
  •  Use voltage (V): 400 | 440
60 days return

Ultrices dolor massa dui curabitur.

Free shipping

Ultrices dolor massa dui curabitur.

newsletter sign up
Email
The form has been submitted successfully!
There has been some error while submitting the form. Please verify all form fields again.