606212 ECRAS 200
3Ø Multimeter
General Seven Segment Display ✔
LCD Screen –
Language Support –
Battery –
Real Time Clock –
Password Protection ✔
Current Transformer Ratio 1 – 5000
Voltage Transformer Ratio 1 – 5000
Demand Period 1-60 min. adjustable
Connection Type 3F4T, 3F3T
Measurements in Quadrants 4
Number of Measurements in a Period 256
LCD/Display Refresh Period 1 sec.
Networks TT, TN, IT
Phasor Diagram –
Signal Waveforms –
Min./Max./Demand Values ✔
Energy Measurement Number of Tariffs 1
Multi Sub-Tariffs (Peak, Day and Off-Peak) –
1Ø Phase Energy Meters ✔
3Ø Phase Energy Meters ✔
4 Quadrant Reactive Energy Meters –
Current Measurement Input Measurement Range 10mA – 6A AC
Overvoltage Category 300 V Cat II
Measurement Surge Voltage 2 kV
Power Consumption <0.2 VA
Intermittent Overload 100 A for 1 sec.
Sampling Frequency between 45-65 Hz 12.8 kHz
Voltage Measurement Input Overvoltage Category 300 V Cat III
Measured Range L-N 1-300 Vrms
Measured Range L-L 2-500 Vrms
Measured Frequency Range 45-65 Hz
Power Consumption <0.1 VA
Sampling Frequency between 45-65 Hz 12.8 kHz
Power Quality Measurements Harmonics for Current and Voltage Phases Up to 31st
THD – Voltage in % ✔
THD – Current in % ✔
Other Measurements Run Hour (Operating Time for Load in Hours) ✔
On Hour (Operating Time for Meter in Hours) Var✔
Int Counter (Number of Power Interruptions) ✔
According to IEC 61557-12 Total Active Power Class 0.5
Total Reactive Power Class 1
Total Apparent Power Class 0.5
Total Active Energy Class 0.5
Total Reactive Energy Class 2
Frequency Class 0.1
Current Class 0.5
Neutral Current Class 0.5
Voltage Class 0.2
Power Factor Class 0.5
THDV, THDI Class 1
According to IEC 62053-22 Total Active Energy Class 0.5S
According to IEC 62053-23 Total Reactive Energy Class 2
Alarm Relay Outputs
Number of Outputs –
Type
Max. Switching Current 10 A
Max. Switching Voltage –
Max. Switching Power –
Digital Inputs Number of Inputs –
Minimum Counting Frequency –
Input Present or Not –
Isolation Level –
Digital Outputs Number of Outputs –
Type –
Switching Voltage Range –
Minimum Switching Frequency –
Isolation Level –
Analog Outputs Number of Outputs –
Range of Outputs 0-5 V, 0-10 V, -5-5 V, -10-10V, 0-20 mA, 4-20 mA –
Isolation –
Voltage AC 85-300V
DC 85-300V
Consumption AC <6VA
DC <3W
Supply Frequency 45-65Hz
Min./Max./Avg. Values Hourly Records
Daily Records
Monthly Records
Data Logging with timestamp Demand
Alarm Records –
Communication Protocol Modbus RTU
Baud Rate 1200-57600 bps adjustable
Parity Number Odd, Even, None
Stop Bit 1
Address 1-247
Isolation 2750V RMS
Mechanical Properties Weight (g) 296 g
Protection Class Front IP40 / Rear IP20
Mounting Type Panel Mount
Supply, Voltage, Current, Relay
Outputs
Stranded: 2.5mm² – 14AWG
Solid:
4mm² – 12AWG, 2×1.5mm² –
2x16AWG
Digital I/O, RS 485, Analog
Output
Stranded: 1.5mm² – 16AWG
Solid:
1.5mm² – 16AWG, 2×0.75mm² –
2x18AWG
Ambient Conditions Operating Temperature -20°C +70°C
Storing Temperature -30°C +80°C
Relative Humidity (No Condensation) Max. 95%
EMC-EMI 300 VAC CAT II according to IEC 61010-1 ✔
EN 55011/A1:2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN
61000-4-8, EN61000-4-11 ✔
Schematics Network Connections
Digital I/O and Alarm Output Connections
3 wires with 3CTs
4 wires with 3CTs
3 wires with 2CTsNOTE: CTs can be connected any phase. They are connected to phase 1 and
phase 3 in this figure.
Single Phase with 1CTNORE: CT and VT can be connected any phase. They are connected to
phase 1 in this figure.
Digital Output Connection
Digital Input Connection
Alarm Output Connection
Analog Output Connection
“CLZ-FP-46/30-HD” has been added to your cart. View cart
606212 ECRAS 200
₨20,000.00
Multimeter ECRAS by KLEMSAN is an advanced multimeter that can measure 3 phases in electric networks and can be controlled by 2 relay outputs. ECRAS offers a very…
Category: Our Products
Description
Reviews (0)
Be the first to review “606212 ECRAS 200” Cancel reply
Shipping & Delivery
Related products
CLZ-FP-44/12,5-HD
₨70,000.00
CLZ-FP-46/15-HD
₨100,000.00
computer SMART III 12
₨402,415.00
CVM-B150-ITF-485-ICT2
₨480,000.00
CVM-C11-FLEX-IN-485-ICT2
₨190,000.00
CVM-C11-FLEX-IN-485-ICT2, Power analyzer 96 x 96
Code: M58561.
- Â Protocol: Modbus/RTU | BACnet
- Â Communications: RS-485
- Â Transistor output: 2
-  Nº relays: 2
- Â Digital inputs: 2
- Â Measuring Channels: 4
- Â Harmonics: 31
- Â Power supply: 100...270 Vac/dc
- Â Input current: 100 mV/kA
- Â Mounting: Pannel
- Â Modules: 96 x 96
CVM-C4-ITF-485-ICT2
₨85,000.00
DAV-72D
₨14,000.00
EM-06
₨16,000.00

Reviews
There are no reviews yet.