General Seven Segment Display ✔
LCD Screen –
Language Support –
Battery –
Real Time Clock –
Password Protection ✔
Current Transformer Ratio 1 – 5000
Voltage Transformer Ratio 1 – 5000
Demand Period 1-60 min. adjustable
Connection Type 3F4T, 3F3T
Measurements in Quadrants 4
Number of Measurements in a Period 256
LCD/Display Refresh Period 1 sec.
Networks TT, TN, IT
Phasor Diagram –
Signal Waveforms –
Min./Max./Demand Values ✔
Energy Measurement Number of Tariffs 2
Multi Sub-Tariffs (Peak, Day and Off-Peak) –
1Ø Phase Energy Meters ✔
3Ø Phase Energy Meters ✔
4 Quadrant Reactive Energy Meters –
Current Measurement Input Measurement Range 10mA – 6A AC
Overvoltage Category 300 V Cat II
Measurement Surge Voltage 2 kV
Power Consumption <0.2 VA
Intermittent Overload 100 A for 1 sec.
Sampling Frequency between 45-65 Hz 12.8 kHz
Voltage Measurement Input Overvoltage Category 300 V Cat III
Measured Range L-N 1-300 Vrms
Measured Range L-L 2-500 Vrms
Measured Frequency Range 45-65 Hz
Power Consumption <0.1 VA
Sampling Frequency between 45-65 Hz 12.8 kHz
Power Quality Measurements Harmonics for Current and Voltage Phases Up to 31st
THD – Voltage in % ✔
THD – Current in % ✔
Other Measurements Run Hour (Operating Time for Load in Hours) ✔
On Hour (Operating Time for Meter in Hours) ✔
Int Counter (Number of Power Interruptions) ✔
According to IEC 61557-12 Total Active Power Class 0.5
Total Reactive Power Class 1
Total Apparent Power Class 0.5
Total Active Energy Class 0.5
Total Reactive Energy Class 2
Frequency Class 0.1
Current Class 0.5
Neutral Current Class 0.5
Voltage Class 0.2
Power Factor Class 0.5
THDV, THDI Class 1
According to IEC 62053-22 Total Active Energy Class 0.5S
According to IEC 62053-23 Total Reactive Energy Class 2
Alarm Relay Outputs
Number of Outputs 2
Type NO (SPST)
Max. Switching Current 10 A
Max. Switching Voltage 250 VAC
Max. Switching Power 1250 VA
Digital Inputs Number of Inputs 1
Minimum Counting Frequency 100 Hz, 10 ms
Input Present or Not Dry Contact
Isolation Level 5000 Vrms
Digital Outputs Number of Outputs 2
Type Transistör
Switching Voltage Range 5-30 VDC
Minimum Switching Frequency 20 Hz, 50 ms
Isolation Level 5000 Vrms
Analog Outputs Number of Outputs —
Range of Outputs 0-5 V, 0-10 V, -5-5 V, -10-10V, 0-20 mA, 4-20 mA —
Isolation —
Voltage AC 85-300V
DC 85-300V
Consumption AC <6VA
DC <3W
Supply Frequency 45-65Hz
Min./Max./Avg. Values Hourly Records —
Daily Records —
Monthly Records —
Data Logging with timestamp Demand —
Alarm Records —
Communication Protocol Modbus RTU
Baud Rate 1200-57600 bps adjustable
Parity Number Odd, Even, None
Stop Bit 1
Address 1-247
Isolation 2750V RMS
Mechanical Properties Weight (g) 323 g
Protection Class Front IP40 / Rear IP20
Mounting Type Panel Mount
Supply, Voltage, Current, Relay
Outputs
Stranded: 2.5mm² – 14AWG
Solid:
4mm² – 12AWG, 2×1.5mm² –
2x16AWG
Digital I/O, RS 485, Analog
Output
Stranded: 1.5mm² – 16AWG
Solid:
1.5mm² – 16AWG, 2×0.75mm² –
2x18AWG
Ambient Conditions Operating Temperature -20 to +70°C
Storing Temperature -30 to +80°C
Relative Humidity (No Condensation) Maks. 95%
EMC-EMI 300 VAC CAT II according to IEC 61010-1 ✔
EN 55011/A1:2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN
61000-4-8, EN61000-4-11 ✔
General
Dimensions
IP 66 Silicon Cover
Silicone
“Power capacitors LV HEAVY DUTY” has been added to your cart. View cart
Description
Reviews (0)
Be the first to review “KLEA 110P” Cancel reply
Shipping & Delivery
Related products
CEM-C21
CEM-C21, three-phase energy meter
Code: Q22332.
- Módules: 4
- Tariff: 1
- Certification: IEC
- Transistor output: 1
- System: Three-phase
- Measure: Direct
- Measurement Range (V): 3 x 127/220...3 x 230/400
- Input current: 5 (65) A
DATA SHEET ⬇️
USER MANUAL ⬇️
CLZ-FP-44/50-HD
₨70,000.00
computer SMART III 12
₨402,415.00
CVM-A1500-ITF-485-ICT2
₨1,450,000.00
CVM-A1500-ITF-485-ICT2, Power quality analyzers with recording of quality events and transients in accordance with (IEC 61000-4-30 Ed.2) Class A
Code: M56311.
- Protocol: Modbus/RTU | BACnet | webserver (HTTP) | XML | HTML5
- Memory: 200 MB
- Memory: Yes
- Events / Waveform: Yes
- Certification: -
- Energy accuracy: 0,2S (.../5A)
- Communications: RS-485 | Ethernet
- Transistor output: 2
- Nº relays: 2
- Digital inputs: 2
- Harmonics: 63
- Input current: .../5 A | .../1 A | 250 mA
- Mounting: Pannel
- Modules: 144 x 144
CVM-C11-FLEX-IN-485-ICT2
₨190,000.00
MYeBOX-1500-4 FLEX-R80
₨5,000,000.00
MYeBOX-1500-4 FLEX-R80, Portable power analyzer with recording of quality events and transients
Code: M8405E. CONSULTAR DISPONIBILIDAD
- Nr Sensors: 4 FLEX-R80
- Communications: Wi-Fi | 3G
- Transistor output: 2
- Digital inputs: 2
- No. of voltage measurement inputs: 5
- Measuring current Channels: 5
- Class: According to Class A
Reviews